Mitech MDC Series Impact test low temperature meter,adopt imported compressor refrigeration technology, heat balance principle and the way of mixing, can achieve the sample of automatic uniform cooling, constant temperature storage, its strong structure, simple structure, easy operation, high efficiency, low temperature impact test material is the best test Like cooling, insulation equipment, but also for other low temperature testing and testing work.
Widely used in low temperature impact test samples of the sample cooling, constant temperature storage.
Impact test low temperature meter,adopt imported compressor refrigeration technology, heat balance principle and the way of mixing, can achieve the sample of automatic uniform cooling, constant temperature storage
l Relative humidity:20%~80%;
l No corrosive medium, no high magnetic field interference;
l Horizontal installation on a solid basis;
l Power supply voltage fluctuation does not exceed 10% of rated voltage.
l Widely used in materials, low temperature impact test sample cooling, constant temperature storage, can also be used for other
low temperature testing and testing work;
l The use of imported compressor refrigeration technology, heat balance principle and the cycle of mixing, high efficiency;
l Strong structure, simple structure, stable performance, easy operation, can also cool a number of test pieces;
l Consistent with GB, ISO, ASTM and other relevant domestic and foreign standards.
l Read the manual carefully before using the instrument. Learn the operation steps and attentions to avoid damage the
instrument or personal safety accidents caused by improper operation;
l Test machine is a large precision instruments, should pay attention to water, moisture. Exposed workstations, upper and
lower beam parts and attached parts should be coated with anti-rust oil to prevent rust;
l The instrument power supply should be reliably grounded and equipped with regulator device;
l To ensure the accuracy of cryogenic instruments,the instrument needs to be checked at least once a year;
Don’t disassemble the instrument without authorization, maintenance related matters please contact MITECH after-sale
service department with 4000600280.
Temperature range | +30℃~- 100℃ |
Constant temperature accuracy | ±0.5℃ |
Cooling rate | +30℃~-40℃ about1.8℃/min 40℃~-80℃ about1.5℃/min |
Effective working space | 150*150*240mm |
The number of samples can be loaded | >100(Impact specimen size:10*10*55mm) |
Digital timer | 1~999min,resolution 1min |
Cooling medium | Ethanol or other antifreeze |
Dimensions mm | 1500*1200*1200 |
Power supply | 220V~240V,50HZ |